Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)

Fabric OS Command Reference 61
53-1001186-01
burninLevel
2
burninLevel
Sets the diagnostics burn-in level.
Synopsis burninlevel [level | -show]
Description Use this command to select or display the burn-in level. When you set the burn-in level to a value
other than 0, this command behaves as follows:
1. The diagnostic daemon program performs burn-in testing in place of the power-on self-test
(POST) phase II each time a switch blade is powered on.
2. The burn-in test stores errors on the local persistent error storage on which the error occurs.
For multi-bladed products, this is the independent blade, and for fixed-port-count products, this
is the chassis-persistent storage.
The behavior of this command is determined by the manner in which the diagnostics daemon is
configured and which burn-in scripts are run. Changes made by this command are effective
immediately; a reboot is not required. Use burninErrShow to view the error logs.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands The following operands are optional:
level The burn-in level sets to this value.
-show If specified, or if level is not specified, the current burn-in level setting
displays.
Examples To set the diagnostic burn-in level:
switch:admin> burninlevel -show
Burnin level is 0.
See Also burninErrShow, diagDisablePost, diagEnablePost