Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)
Fabric OS Command Reference 59
53-1001186-01
burninErrClear
2
burninErrClear
Clears errors stored in nonvolatile memory during burn-in.
Synopsis burninerrclear slotnumber
Description Use this command to clear errors that were stored during burn-in in the nonvolatile memory of a
specified slot.
It is advisable to run the burninErrClear command prior to running diagSetCycle
.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands The following operand is required:
slotnumber Specify a nonzero value for the slot number from which to clear burn-in errors.
Examples To clear burn-in errors from slot 2:
switch:admin> burninerrclear 2
See Also burninErrShow