Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)
788 Fabric OS Command Reference
53-1001186-01
systemVerification
2
-fru type Tests a single FRU in the system. Valid values are BLADE, PS, FAN, and WWN;
however, only BLADE is supported at this time. Since only one FRU type is
supported, this parameter is optional, but -unit is required for single FRU
testing.
-unit id Tests a single FRU in the system. Specify a FRU ID of type of BLADE. The FRU
ID is the slot number of the FRU to be tested.
Diagnostics Each diagnostic test in this suit reports its own set of error messages when detecting a failure.
Refer to the Diagnostics section of individual diagnostic test help pages. These messages are
available only in the log file.
Refer to the Fabric OS Message Reference for more information.
Examples To initiate a system verification test on all switches in the fabric:
switch:admin> systemverification -short
systemverification: Setting parameters for short run.
systemverification: burnin parameters.
CURRENT - KEYWORD : DEFAULT
1 - number_of_runs : 1
2 - vib : 2
10 - thermal : 10
SYSTEMVERIFICATION - label : BURNIN
2 - min_lb_mode : 2
1 - tbr_passes : 1
1 - prt_on : 1
1 - cntmem_on : 1
1 - cmi_on : 1
1 - retention_on : 1
1 - cam_on : 1
1 - flt_passes : 50
1 - sta_passes : 25
1 - plb_nframes : 100
1 - txd_nframes : 50
1 - xpt_nframes : 200
1 - bpt_nframes : 20
1 - slk_nmegs : 50
1 - bpt_all_nframes : 30
1 - slk_all_nmegs : 50
systemverification: Arming the burnin run on switch 0.
systemverification: Starting burnin on Switch 0
systemverification: Monitoring progress of the burnin activity.
systemverification: Outputting Status
State Status Run Cmd TotCmds Script
COMPLETED PASS 1 22 22 switchburnin.sh
See Also burninErrShow, burninStatus, diagSetCycle