Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)
584 Fabric OS Command Reference
53-1001186-01
portCfgShow
2
To display VLAN tagging on a GbE port (refer to the portCfg help page for an explanation of the
displayed parameters):
switch: admin> portcfgshow vlantag 8/ge0
Port: 8/ge0
IpIfAddress VlanId L2 CoS Dest IP Address Flags
-----------------------------------------------------
192.168.10.1 100 7 192.168.10.1 App
192.168.10.1 100 3 0.0.0.0 Perm
To display inband management interfaces configured on the Brocade 7500:
switch:admin> portcfgshow inbandmgmt ge1
Inband management: Enabled
Port: ge1
CP Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.1 255.255.255.252 1500
Port: ge1
GE Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.2 255.255.255.252 1500
See Also portCfg, portCfgCreditRecovery, portCfgEport, portCfgGport, portCfgLongDistance,
portCfgLPort, portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort