Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)

582 Fabric OS Command Reference
53-1001186-01
portCfgShow
2
To display the configuration settings for a port with Access Gateway enabled:
SW4016_5311:admin> portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Locked N_Port .. .. .. .. .. .. .. .. .. .. ON ON .. ON ON ON
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
where AN:AutoNegotiate, ..:OFF, ??:INVALID, LM:L0.5
To display the configuration settings for a single port:
switch:admin> portcfgshow 2/16
Area Number: 144
Speed Level: AUTO
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
QOS E_Port ON
Mirror Port OFF
Port Auto Disable ON
To display FCIP tunnels configured on a GbE port. (refer to the portCfg help page for an explanation
of the displayed parameters):
switch:admin> portcfgshow 10/ge0
Mode: FCIP
Persistent Disable: OFF
Ipif configuration:
Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.60.100 255.255.255.0 1500
1 192.168.60.101 255.255.255.0 2348
2 192.168.60.102 255.255.255.0 1260
3 192.168.60.103 255.255.255.0 1700
4 192.168.60.104 255.255.255.0 1400
5 192.168.60.105 255.255.255.0 2000
6 192.168.60.106 255.255.255.0 1300
7 192.168.60.107 255.255.255.0 2200
Interface IPv6 Address Len MTU
-----------------------------------------------------------
Arp configuration:
IP Address Mac Address