Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)

330 Fabric OS Command Reference
53-1001186-01
haDump
2
Examples To view information about the High Availability feature status:
switch:admin> hadump
Local CP (Slot 6, CP1): Active, Cold Recovered
Remote CP (Slot 5, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
SWITCH
Ethernet IP Address: 10.32.227.64
Ethernet Subnetmask: 255.255.240.0
Fibre Channel IP Address: 220.220.220.64
Fibre Channel Subnetmask: 255.255.240.0
CP0
Ethernet IP Address: 10.32.227.66
Ethernet Subnetmask: 255.255.240.0
Host Name: cp0
Gateway IP Address: 10.32.224.1
CP1
Ethernet IP Address: 10.32.227.67
Ethernet Subnetmask: 255.255.240.0
Host Name: cp1
Gateway IP Address: 10.32.224.1
Slot 10
eth0: 10.32.227.69/20
Gateway: 10.32.224.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
IPv6 Autoconfiguration Enabled: No
Local IPv6 Addresses:
sw 0 static fec0:60:69bc:64:260:69ff:fee4:3a/64
cp 0 static fec0:60:69bc:64:205:1eff:fe25:9c1/64
cp 1 static fec0:60:69bc:64:205:1eff:fe02:a197/64
FSSME registered: TRUE
[output truncated]
See Also haFailover, haShow