Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)
732 Fabric OS Command Reference
53-1001764-01
portLoopbackTest
2
To run a functional test on a Brocade 8000:
switch:admin> pceeportloopbacktest
Running portloopbacktest ..............
PASSED.
Diagnostics When it detects failures, the test may report one or more of the following error messages. If errors
persist, contact Technical Support.
DATA Data received does not match the data sent.
ERRSTAT Errors were found in the ASIC statistics.
INIT Port failed to initialize.
PORTDIED A previously initialized port went to an uninitialized state.
STATS Errors were found in the ASIC statistics.
TIMEOUT Did not receive a frame in the given timeout period.
XMIT Frame transmission failure.
See Also itemList