Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)
686 Fabric OS Command Reference
53-1001764-01
portCfgSpeed
2
ax Autosensing mode (hardware). The port automatically configures for
maximum speed with enhanced retries.
s Auto-sensing mode (software). The port automatically configures for
maximum speed with enhanced retries.
1 The port is set at a fixed speed of 1 Gbps.
2 The port is set at a fixed speed of 2 Gbps.
4 The port is set at a fixed speed of 4 Gbps.
8 The port is set at a fixed speed of 8 Gbps.
-h Displays the command usage.
Examples To set the speed of a port to 4 Gbps:
switch:admin> portcfgspeed 2/3 4
To set the speed of a port using the port index:
switch:admin> portcfgspeed -i 78 8
To set the speed of a port range using the port index:
switch:admin> portcfgspeed -i 24-38 8
To set all ports on slots 2 and 3 to 8 Gbps:
switch:admin> portcfgspeed -s 2-3
To set all ports on slots 2-3 and 9-12 to 8 Gbps:
switch:admin> portcfgspeed -s 2-3 9-12
See Also portCfgShow, portShow, switchCfgSpeed, portSwapDisable, portSwapShow, switchShow