Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)

674 Fabric OS Command Reference
53-1001764-01
portCfgShow
2
portCfgShow
Displays port configuration settings.
Synopsis portcfgshow
portcfgshow [slot/]port
portcfgshow -i [index1[-index2] [...] [-f]]
portcfgshow -slot slot1[-slot2] [...]
portcfgshow option [slot/][ge_port] [arguments] [optional_arguments]
Description Use this command to display the current configuration of a port. The behavior of this command is
platform-specific; output varies depending on port type and platform, and not all options are
supported on all platforms.
“Non-GbE port displays”
When used without operands, this command displays port configuration settings for all ports on a
switch, except Gigabit Ethernet (GbE) ports.
“Displays supported only on the Brocade 7800 /FX8-24 and on the Brocade 7500/7500E/FR4-18i
platforms”
Use this command with optional arguments to display the following parameters configured for a
GbE port on the Brocade 7800/FX8-24 and on the Brocade 7500/7500E/FR4-18i platforms.
IP interfaces on the GbE port
Static routes on the IP interfaces
Address resolution protocol (ARP) entries
VLAN tag configuration
Fibre Channel over IP (FCIP) tunnel configuration settings
- IPSec configuration
- QoS mappings (Brocade 7500/7500E/FR4-18i only)
“Displays supported only on the Brocade 7500/7500E/FR4-18i platforms”
Port mode information
Inband Management IP addresses and routes (Brocade 7500 only)
Non-GbE port displays
The following information is displayed when the command is issued for all ports, for a single port,
or for one or more port ranges specified by their port index numbers or slot numbers:
Area Number Displays the port area number. This field is displayed only when portCfgShow
is executed for a single port.
Speed Displays Auto for auto speed negotiation mode, or a specific speed of 1, 2, 4,
or 8 Gbps. This value is set by the portCfgSpeed command.
Fill Word Displays one of the following numeric values: 0(Idle-Idle), 1(arbff-arbff),
2(Idle-arbff), or 3(A-A then SW I-A).This parameter is set by the portcfgFillword
command.