Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)
Fabric OS Command Reference 369
53-1001764-01
fwFruCfg
2
fwFruCfg
Displays or modifies FRU state alert configuration.
Synopsis fwfrucfg [--show]
Description Use this command to configure field-replaceable unit (FRU) states and actions. Based on these
configuration settings, Fabric Watch generates actions when a FRU state changes. When used
without operand, this command interactively prompts for user input. To configure email alerts, use
fwMailCfg. This command is not applicable to platforms that do not support FRUs.
Notes This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operand:
--show Displays the current FRU configuration setting. This operand is optional; if
omitted, the configuration prompt displays.
Examples To change the FRU state alert configuration:
switch:admin> fwfrucfg
The current FRU configuration:
Alarm State Alarm Action
-----------------------------------------------
Slot 0 1
Power Supply 0 0
Fan 0 0
WWN 0 0
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0] 3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed
See Also fwHelp, fwMailCfg