Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)
Fabric OS Command Reference 205
53-1001764-01
diagEnablePost
2
diagEnablePost
Enables the power-on self-test (POST).
Synopsis diagenablepost
Description Use this command to enable POST. A reboot is not required for this command to take effect. POST
includes two phases: POST Phase I mainly tests hardware and POST Phase II tests system
functionality.
Use the diagPost command to display the current POST status, and use diagDisablePost to disable
POST.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands none
Examples To enable POST:
switch:admin> diagenablepost
Config update Succeeded
Diagnostic POST is now enabled.
See Also diagDisablePost, diagPost