Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)
170 Fabric OS Command Reference
53-1001764-01
cryptoCfg
2
- Operation in progress. Displays one of the following:
• Read Phase
• Write Phase
• HA Sync Phase
• LUN Cleanup
- VI: virtual initiator port WWN and node WWN
- VI PID: virtual initiator PID
- Number of blocks: numeric value
- Block size: numeric value (in KB)
- Size of the LUN (in bytes)
- Current logical block address (LBA) being processed
- Rekey Role: Primary Or Backup
Use the --show -tape_sessions command to display all tape sessions in progress on the local
node or for a specific container. The display includes the following information:
• Number of tape sessions in progress: numeric value
• Container name: user-defined label
• EE node name: node WWN
• EE Slot Number: slot number
• Target: target port WWN and node WWN
• Target PID: Target PID
• VT: virtual target port WWN and node WWN
• VT PID: virtual target PID
• Host: host port WWN and node WWN
• Host PID: host PID
• VI: virtual initiator port WWN and node WWN
• VI PID: virtual initiator PID
• LUN number: numeric identifier
• Tape session number: numeric identifier
• For each Tape session:
- Number of uncompressed blocks: numeric value
- Number of compressed blocks: numeric value
- Number of uncompressed bytes: numeric value
- Number of compressed bytes: numeric value
Notes Encryption groups and HA clusters must be configured before performing any CryptoTarget
container and Crypto LUN configurations.
When adding a LUN to a CryptoTarget container, special attention should be paid to the input
format. A LUN number can be entered either as a 16-bit (2 bytes) number in hex notation (for
example, 0x07) or as a 64-bit (8 bytes) number in WWN format (for example,
00:07:00:00:00:00:00:00). Although the command does accept decimal input, it is not
recommended. The conversion function used to parse the LUN number converts a decimal number