Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.4.0 (53-1001764-01, March 2010)

138 Fabric OS Command Reference
53-1001764-01
configure
2
Zoning Operation Parameters
Table 9 lists the configurable zoning operation parameters.
Disable NodeName Zone Checking
Specify 1 to disable using node WWN when specifying nodes in the zone
database, or specify 0 to enable using node WWN when specifying nodes in
the zone data. The default value is 0. This value must be set to 1 for
interpretability.
RSCN Transmission Mode
Table 10 lists the RSCN transmission mode values fields.
End-device RSCN Transmission Mode values are as follows:
0 RSCN only contains single PID
1 RSCN contains multiple PIDs
2 Fabric addresses RSCN
Domain RSCN to End-device for switch IP address or name change values are as follows:
0 Disabled. No domain RSCN is sent to the end-device for the switch IP address
or name change.
1 Enabled. Domain RSCN is sent to the end-device for the switch IP address or
name change.
Arbitrated Loop Parameters
The Arbitrated Loop Setting fields are described in Table 11.
Descriptions of the Arbitrated Loop Parameter fields are as follows:
Send FAN frames? Specifies that fabric address notification (FAN) frames be sent to public loop
devices to notify them of their node ID and address. When set to 1, frames
are sent; when set to 0, frames are not sent.
TABLE 9 Zoning operation parameters
Field Type Default Range
Disable NodeName Zone Checking Boolean 0 1
TABLE 10 RSCN transmission modes
Field Type Default Range
End-device RSCN Transmission Mode number 1 0 to 2
Domain RSCN to End-device for switch IP address or name change number 0 0 to 1
TABLE 11 Configure command arbitrated loop settings
Field Default Range
Send FAN frames? 1 0 or 1
Enable CLOSE on OPEN received? 4 0 to 4
Always send RSCN? 0 0 or 1