Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)
694 Fabric OS Command Reference
53-1001337-01
portShow
2
To display port status for a 1 GbE port on a Brocade 7800 Extension switch:
switch:admin> portshow ge2
Eth Mac Address: 00.05.1e.54.b1.17
Port State: 1 Online
Port Phys: 6 In_Sync
Port Flags: 0x4003 PRESENT ACTIVE LED
Port Speed: 1G
To view xlate domains, you must issue the command on a Brocade 7500/7500E or a chassis with
an FR4-18i blade. Note that the Front Domain ID is what is shown:
switch:admin> portshow 8/4
portName:
portHealth: No Fabric Watch License
Authentication: None
EX_Port Mode: Enabled
Fabric ID: 20
Front Phantom: State: OK
Cur Dom ID: 160 WWN: 50:00:51:e3:60:ee:0e:14
Pr Switch Info: Dom ID: 5
WWN: 10:00:00:05:1e:34:02:04
Fabric params: R_A_TOV: 10000 E_D_TOV: 2000 PID fmt: core
Authentication Type: None
Hash Algorithm: N/A
DH Group: N/A
Edge fabric's primary wwn: N/A
Edge fabric's version stamp: N/A
portDisableReason: None
portCFlags: 0x1
portFlags: 0x903 PRESENT ACTIVE G_PORT U_PORT
EX_PORT LOGICAL_ONLINE LOGIN
portType: 10.0
portState: 1 Online
portPhys: 6 In_Sync
portScn: 1 Online Trunk master port
port generation number: 160
portId: 965400
portIfId: 43820005
portWwn: 20:54:00:05:1e:36:0e:e0
portWwn of device(s) connected:
Distance: normal
portSpeed: N2Gbps
LE domain: 0
Interrupts: 49 Link_failure: 0 Frjt: 0
Unknown: 0 Loss_of_sync: 2 Fbsy: 0
Lli: 27 Loss_of_sig: 4
Proc_rqrd: 143 Protocol_err: 0
Timed_out: 0 Invalid_word: 0
Rx_flushed: 0 Invalid_crc: 0
Tx_unavail: 0 Delim_err: 0
Free_buffer: 0 Address_err: 1
Overrun: 0 Lr_in: 2
Suspended: 0 Lr_out: 2