Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)
360 Fabric OS Command Reference
53-1001337-01
haShow
2
Operands none
Examples To display CP status on a Brocade 48000, first on a healthy standby CP and then on a faulty
standby CP:
switch:admin> hashow
Local CP (Slot 6, CP1): Active, Cold Recovered
Remote CP (Slot 5, CP0): Non-Redundant
switch:admin> hashow
Local CP (Slot 6, CP1): Active, Warm Recovered
Remote CP (Slot 5, CP0): Standby, Failed
Backplane PCI fail, severity: CRITICAL
HA enabled, Heartbeat Up, HA State not in sync
To display CP status on a Brocade DCX with a healthy standby CP:
switch:admin> hashow
Local CP (Slot 7, CP1) : Active, Cold Recovered
Remote CP (Slot 6, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
See Also haDisable, haEnable, haFailover