Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)
Fabric OS Command Reference 187
53-1001337-01
diagEnablePost
2
diagEnablePost
Enables power-on self-test (POST) execution at next reboot.
Synopsis diagenablepost
Description Use this command to enable POST. A reboot is not required for this command to take effect. POST
includes two phases: POST Phase I mainly tests hardware and POST Phase II tests system
functionality.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands none
Examples To enable the POST:
switch:admin> diagenablepost
Config update Succeeded
Diagnostic POST is now enabled.
See Also diagDisablePost