Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

154 Fabric OS Command Reference
53-1001337-01
cryptoCfg
2
- Rekey: disabled or enabled
- Key ID state: Read, Write, or Key ID not applicable
- Key life (in days): numeric value
- Volume/pool label: user-defined label
- Rekey status: numeric value
If re-key or tape sessions are in progress, the command shows:
Number of re-key sessions in progress: numeric value
For each re-key session the display includes:
- Re-key session number: numeric value
- Percent completion: numeric value
- Re-key state: Read or Write phase
- Tape volume/pool Label: user-defined label
- Tape state: mounted or unmounted
- Tape policy configuration details:
Tape pool or tape
Encryption or Cleartext
Key life span in days
Encryption Algorithm
Compression Algorithm
Number of Tape sessions in progress: numeric value
For each Tape session the display includes:
- Tape Session Number: numeric value
- Number of uncompressed blocks: numeric value
- Number of compressed blocks: numeric value
- Number of uncompressed bytes: numeric value
- Number of compressed bytes: numeric value
Use the --show -rekey command to display all re-key sessions in progress in the encryption group
or for a specified container. The display includes the following information:
Number of re-key sessions in progress: numeric value
For each re-key session, the display includes:
- Container name: user-define label
- EE node: node WWN
- EE slot: Slot number
- Target: target port WWN and node WWN
- Target PID: target PID
- VT: virtual target port WWN and node WWN
- VT PID: virtual target PID
- Host (initiator) PWWN
- Host (initiator): node WWN