Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)
Fabric OS Command Reference 127
53-1001337-01
configure
2
Descriptions of the Arbitrated Loop Parameter fields are as follows:
Send FAN frames? Specifies that fabric address notification (FAN) frames be sent to public loop
devices to notify them of their node ID and address. When set to 1, frames
are sent; when set to 0, frames are not sent.
Enable CLOSE on OPEN received?
If this is set, a CLS is returned immediately to an OPN if no buffers are
available. This is required for TachLite.
Always send RSCN? Following the completion of loop initialization, a remote state change
notification (RSCN) is issued when FL_Ports detect the presence of new
devices or the absence of pre-existing devices. When set to 1, an RSCN is
issued upon completion of loop initialization, regardless of the presence or
absence of new or pre-existing devices.
System Services Settings
Settings affecting System Services are described in Table 8.
TABLE 8 Disable RLS probing
Disable RLS probing Enables or disables the read link status (RLS) probing. Performed by the FCP
daemon, RLS probing reads the link error block from the device. This
extended link services command is defined by the FC standards. Refer to the
FC standards for information. This parameter is enabled (“on”) by default;
“off” disables RLS probing.
Portlog Events Enable/Disable Settings
These settings determine whether or not various types of port events are logged.
Each event type displayed on the screen is enabled by default (“on”). When disabled, this event is
not logged by the port log.
Application Attributes
Table 9 lists configurable application attributes. By default, all application attributes are enabled.
Field Type Default Range
Disable RLS probing
Boolean off off or on
TABLE 9 Configurable application attributes
Application File Type Default Range
ssl Certificate File string not set varies
CA Certificate File string not set varies
Length of crypto key number 128 40, 56, 128
rpcd Secure RPCd Callback secret string none varies
Webtools Basic User Enabled boolean no no/yes
Perform License Checking and Warning boolean yes yes/no
Allow Fabric Event Collection boolean yes yes/no
Login Session Timeout (in seconds) number 7200 60 to 432000