Brocade Fabric OS Administrator's Guide Supporting Fabric OS v6.3.0 (53-1001336-02, November 2009)

266 Fabric OS Administrator’s Guide
53-1001336-02
FC4-16IP blade configuration
12
FC4-16IP blade configuration
This section describes the initial setup required to deploy an iSCSI gateway solution. Install and
configure the FC4-16IP blade in a Brocade 48000 as described in the Brocade FC4-16IP Hardware
Reference Manual before performing these procedures.
NOTE
Only the Brocade 48000 with an iSCSI-enabled FC4-16IP blade running Fabric OS v6.1.0 or later
supports the iSCSI gateway service.
NOTE
You can also configure an FC4-16IP blade through the Web Tools Graphical User Interface as an
alternative to the command line interface. Refer to the Web Tools Administrator’s Guide for
descriptions of GUI-based configuration procedures.
FC4-16IP port numbering
The FC4-16IP blade has both GbE ports and FC ports. Ports are addressed using slot number and
port number notation, for example, 2/7. FC ports are numbered from 0 through 7; GbE ports are
numbered from ge0 through ge7.
NOTE
The FC4-16IP blade does not support FCIP functionality.