Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 185
53-1000600-02
FSS-1007
28
Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is
not healthy. The error occurs when the standby CP does not respond to a request from the active
CP within 5 seconds. This usually indicates a problem with the internal Ethernet connection and a
disruption of the synchronization process.
Recommended
Action
Check the Ethernet connection between active CP and standby CP (interface eth1) by issuing net
commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network
configuration; then try to restore the synchronization by issuing the haSyncStart command. If the
problem persists, contact your switch service provider.
Severity CRITICAL