Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

150 Fabric OS Message Reference
53-1000600-02
FICN-1005
23
FICN-1005
Message <timestamp>, [FICN-1005], <sequence-number>,, INFO, <system-name>, FICON GEPort
<GE port number> TID <tunnel number> Feature Change verified Xrc <1 or 0 - XRC
Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or
Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled or Disabled> TinTir
<1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON
Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 - FICON Write
Emulation Read Block ID Emulation Enabled or Disabled>.
Probable Cause User changed the configuration manually.
Recommended
Action
No action is required.
Severity INFO
FICN-1006
Message <timestamp>, [FICN-1006], <sequence-number>,, WARNING, <system-name>, FICON
GEPort < 0 or 1 - GE port number> TID <Tunnel Number> Feature Change failed Xrc <1
or 0 - FICON XRC Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write
Emulation Enabled or Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled
or Disabled> TinTir <1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck
<1 or 0 - FICON Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 -
FICON Write Emulation Read Block ID Emulation Enabled or Disabled>.
Probable Cause The FCIP Tunnel ID associated with the FICON tunnel must be down or disabled for a feature
change to become effective.
Recommended
Action
Disable the applicable FCIP tunnel to make the feature change effective.
Severity WARNING
FICN-1007
Message <timestamp>, [FICN-1007], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Selective Reset:Path=<FICON PATH> State=0x<current FICON
Emulation State> stat_array=0x<last 4 FICON Emulation states>.
Probable Cause Selective Reset from the channel received as either a normal part of path recovery or starting
sequence in an error case.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support.
Severity ERROR