Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 83
53-1000600-02
EM-1028
12
Recommended
Action
Either change the chassisConfig option to 1 with the chassisConfig command, or upgrade the
firmware on the standby to the version running on the active CP.
Severity WARNING
EM-1028
Message <timestamp>, [EM-1028], <sequence-number>, FFDC, CRITICAL, <system-name>, HIL
Error: <function> failed to access history log for FRU: <FRU Id> (rc=<return
code>).
Probable Cause Indicates a problem accessing the data on the world-wide name (WWN) card field-replaceable unit
(FRU), or the WWN card storage area on the main logic board.
The problems were encountered when the software attempted to write to the history log storage to
record an event for the specified FRU. The return code is for internal use only. This is a serious
hardware problem.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot,
or port.
Recommended
Action
If the message persists, reboot or power cycle the switch.
If the message still persists, replace the WWN card, or the switch (for nonbladed switches).
Severity CRITICAL
EM-1029
Message <timestamp>, [EM-1029], <sequence-number>,, WARNING, <system-name>, <FRU Id>, a
problem occurred accessing a device on the I2C bus (<error code>). Operational
status (<state of the FRU when the error occurred>) not changed, access is being
retried.
Probable Cause Indicates that the I2C bus had problems and a timeout occurred.
Recommended
Action
This is often a transient error.
Watch for the EM-1048 message, which indicates that the problem has been resolved.
If the error persists, check for loose or dirty connections. Remove all dust and debris prior to
reseating the field-replaceable unit (FRU). If it continues to fail, replace the FRU.
Severity WARNING
EM-1031
Message <timestamp>, [EM-1031], <sequence-number>,, ERROR, <system-name>, <FRU Id>
ejector not closed.
Probable Cause Indicates that the environmental monitor (EM) has found a switch blade that is inserted, but the
ejector switch is not closed. The blade in the specified slot is treated as not inserted.