Brocade Access Gateway Administrator's Guide v6.2.0 (53-1001189-01, April 2009)

6 Access Gateway Administrators Guide
53-1001189-01
Access Gateway limitations
1
Access Gateway limitations
The limitations of Access Gateway are as follows:
Limited to switch platforms and embedded switch platforms listed in “Supported hardware and
software” on page xiii.
Maximum number of AGs that can be connected to an Edge switch is 30
Maximum number of devices that can be connected to a Fabric OS switch through AG depends
on the maximum number of local devices supported by Fabric OS.
AG does not support loop devices.
Upgrade and downgrade considerations for switches in AG mode
Downgrading to Fabric OS v6.1.0 or earlier is supported; however, you must first disable the switch
from AG mode. Note the following considerations when upgrading and downgrading from Fabric OS
v6.2.0 to Fabric OS v6.1.0 and earlier:
Downgrades to v6.0.0 or earlier Fabric OS versions are not allowed if any F_Port trunk is
active.
Trunking must be disabled before downgrading to Fabric OS v6.0.0 or earlier.
When a switch is set in AG mode, if you downgrade to v6.0.0x, all preferred Failover
settings are lost.
The following table describes the scenarios for upgrading and downgrading Fabric OS versions.
TABLE 3 Description of F_Port-to-N_Port mapping
Access Gateway Fabric
F_Port N_Port Edge switch F_Port
F_1, F_2 N_1 Switch_A F_A1
F_3, F_4 N_2 Switch_A F_A2
F_5, F_6 N_3 Switch_B F_B1
F_7, F_8 N_4 Switch_B F_B2
TABLE 4 Firmware upgrade and downgrade scenarios
Policies Fabric OS v6.2 -> 6.1 Fabric OS v6.1 -> 6.2 Fabric OS v6.2 -> 6.0
Auto Port Configuration Yes Yes Yes
Port Grouping Yes Yes No
Port Trunking
(with trunk members OFFLINE)
Yes Yes No
Port Trunking
(with trunk members ONLINE)
Yes Yes No
Advance Device Security Policy Yes Yes No