User guide
Troubleshooting iLO 2 189
LED indicator POST code
(activity
completed)
Description Failure indicated
4, 3, and 1 0d Boot Block Main started. Boot block could not find a
valid image.
None
Start C Run time
initialization.
4, 3, and 2 0e Main() has received control. Main self-test failed.
Varies Varies Each subsystem may self-
test.
4, 3, 2, and 1 0f Start ThreadX. RTOS startup failed.
None 00 Main_init() completed. Subsystem startup failed.
HB and 7
Flashes as the iLO 2
processor executes
firmware code. It does not
change the value of the
lower six LEDs.
The iLO 2 microprocessor firmware includes code that makes consistency checks. If any of these checks
fail, the microprocessor executes the FEH. The FEH presents information using the iLO 2 POST LED
indicators. The FEH codes are distinguished by the alternating flashing pattern of the number 99 plus the
remainder of the error code.
FEH code Consistency check Explanation
9902 TXAPICHK An RTOS function was called with an
inappropriate value or from an inappropriate
caller.
9903 TXCONTEXT The saved context of one or more threads has been
corrupted.
9905 TRAP A stack probe failed, the return address is invalid,
or an illegal trap instruction has been detected.
9966 NMIWR An unexpected write to low memory has occurred.
99C1 CHKNULL The reset vector has been modified.
Event log entries
Event log display Event log explanation
Server power failed Displays when the server power fails.
Browser login: IP address Displays the IP address for the browser that logged
in.
Server power restored Displays when the server power is restored.
Browser logout: IP address Displays the IP address for the browser that logged
out.
Server reset Displays when the server is reset.
Failed Browser login – IP Address: IP address Displays when a browser login fails.