5.
Close the processor retaining latch and the processor socket retaining bracket.
6. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab.
Allow the alcohol to evaporate before continuing.
7. Apply all the grease to the top of the processor in one of the following patterns to ensure even
distribution:
8. Install the heatsink ("Heatsink" on page 36).
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
9. Install all components removed from the failed system board.
10. Install the hard drives ("Hard drive" on page 25).
11. Install the hard drive blanks ("Hard drive blank" on page 25).
12. Install the access panel ("Access panel" on page 24).
13. Power up the server blade.