User's Manual
6-142 HP Designjet T Series — Service Manual
Removal and Installation 
Scan-Axis Motor (T1100/T1100ps/T610)
Removal
1. Remove the Right Cover on page 6-27.
2. Remove the 
Left Cover on page 6-30.
3. Loosen the T-10 uncapping screw 
sufficiently so you can manually move the 
Carriage Assembly in step 4.
If you are uncapping a 44 inch 
printer, you will need to use either 
a very long or very short 
screwdriver to loosen the 
uncapping screw. In this way, you 
can loosen the screw and pass the 
rewinder motor.
4. Push the Carriage Assembly into the print 
path.
5. Loosen the T-15 screw Belt Tensioner to the 
printer to remove the tension from the belt.
Switch off the printer and remove the power cable.
44 inch T1100 printer shown (with Rewinder)