Service Calibrations 
4-12 HP Designjet T Series — Service Manual
24 Load the Calibration Pattern following the instructions on the Front Panel. 
Once the Calibration Pattern is loaded correctly, the following message will 
be displayed on the Front Panel. Press the OK key to continue.
25 The Printer will scan the Calibration Pattern which could take several 
minutes. Once the calibration is completed successfully, the following 
message will be displayed on the Front Panel. Press the OK key to continue.
If the Paper Advance Calibration fails for any reason, a warning message 
will appear on the Front Panel. In this case, try the following:
 Check that the Calibration Pattern was not incorrectly cut (trimming the 
actual pattern) during the media load process. If this is the case, perform 
the Paper Advance Calibration again from step 1.
 Perform a Line Sensor Calibration. See Line Sensor Calibration on page 
4-15.
 Replace the Line Sensor. See Line Sensor (T1120/T1120ps) on page 6-
157.
 If the problem continues, replace the Media Advance Driver. See Media 
Advance Drive on page 6-218.
Drop Detector Calibration
The purpose of this Service Calibration is to calibrate the Drop Detector 
(located in the Service Station) in relation to the Carriage Assembly. There 
are two menu options to calibrate the Drop Detector:
 Calibrate Drop Detector
 Reset Calibration Flag
Always perform the Reset Calibration Flag calibration BEFORE calibrating 
the drop detec
tor.
Service calibrations also need to be performed after removing or replacing 
cer
tain pr
inter components. If you have removed or replaced printer 
components, check the 
Service Calibration Guide to Removal and 
Installation on page 6-5 to see which tests and calibrations you need to 
perform.
Reset Calibration Flag
1 In the S
ervice Calibrations submenu, scroll to Drop D
etector Calibration 