HP Designjet T Series — Service Manual 3-7
Service Tests (Diagnostics)
 System Error Code 42:XZ.
 System Error Code 47:XZ.
 System Error Code 73:XZ.
 System Error Codes related to Scan-Axis shutdown or Carriage jam.
Diagnostic tests also need to be performed after removing or replacing 
certain pr
inter components. If you have removed or replaced printer 
components, check the 
Service Calibration Guide to Removal and 
Installation on page 6-5 to see which tests and calibrations you need to 
perform.
ALL THE COVER SENSORS ARE DISABLED WHEN IN THE 
SERVICE TESTS MENU. IF THE CARRIAGE IS MOVING IT WILL 
NOT STOP IF THE WINDOW IS OPENED, SO BE VERY CAREFUL 
NOT TO PUT YOUR HANDS INSIDE.
IF POSSIBLE, ALWAYS PERFORM THIS TEST BEFORE 
REPLACING ANY COMPONENT OF THE SCAN-AXIS.
Star Wheel Lifter test
The Star Wheel Lifter subassembly is designed to move the Start Wheel 
supp
ort to the up and down positions. This is used to load roll or sheet 
media and avoid damage to the Star Wheel caused by paper jams etc.
Perform the Scan Axis - Starwheel lifter test as follows:
Perform this test with the Printheads and the Tubes System 
installed in order to get values that can be compared 
correctly.
1 In the Diagnostics menu, scroll to 1. Scan Axis and press OK.
2 The Front Panel will show the 1. Scan Axis submenu.
3 In the Scan Axis submenu, scroll to Star Wheel Lifter and press OK to 
start the test.
If there is a Failure at any point during the tests, the Front Panel will display 
the relev
ant System Error Code. To trouble shoot any displayed error 
codes, see 
System Error Codes - Full Descriptions on page 2-7.