HP StorageWorks Fabric OS V3.2.1b Release Notes (AA-RUQYG-TE, September 2006)

Supported product m
odels
Fabric OS 3.2.1b fi
rmware is supported on the following switches only.
HP StorageWorks MSA SAN switch 2/8 (SilkWorm 3000)
HP StorageWorks SA N Switch 2/16 (SilkWorm 3800)
Operating systems
See http://www.hp.com for a list of supported operating systems.
Fixes
Table 1 lists d efects that have been closed since the release of Fabric OS 3.2.1.
Table 1 C losed de
fects
Closed Defects
Third party tape drives did not respond to Login (L) bit, based on switch lock L port
configuration
.
After ex ecuting switchdisable or switchenable in a large, secure fabric, some SAN
Switch 2/16 models experienced queue overflow and rebooted.
During in-house testing on large fabrics, all switches in a 30-switch fabric become isolated.
Using Web Too
ls,receivedapopupmessageNOPERFORMANCELICENSE during
basic monito
ring.
If not upgrading to this la test release, the workaround is to install the Advanced Performance
Monitoring (APM) license.
config upload failed on switches supporting a large Zone database.
If not upgrading to this latest release, the workaround is to save the config database
using the CLI.
The SAN Switch 2/16 running 3.2.0 panics during zoning updates in Interop mode.
SAN Switch 2
/16 models used incorrect buffer-to-buffer (BB) credits when switch BB credit
was set les
sthandeviceBBcredit.
If not upgr
ading to this latest release, the workaround is to increase the switch BB credit
limit to >=
device BB credit limit.
Short burst of bad primitives on the link causes rx_under flow error.
If two or more ports zoned together on a SAN Switch 2/16, ZONEGROUPADD FAIL
message displayed.
Email con
figured via Fabric Watch was not received on certain third party mail servers.