HP StorageWorks Fabric OS Procedures V3.1.x/4.1.x User Guide (AA-RS23C-TE, June 2003)

Troubleshooting
220 Fabric OS Procedures Version 3.1.x/4.1.x User Guide
To check all switches attached components (on an FC loop), see “Check
All Switch Components Between Main Board, SFP, and Fiber Cable” on
page 223.
To check all of a port’s attached components (on an FC loop), see “Check
Port’s External Transmit and Receive Path” on page 225.
To view a list of additional component tests, see “Additional Component
Tests on page 228.
Test Cascaded Switch ISL Links
To tests components to/from a neighbor switch:
1. Log into the switch as admin.
2. Enter the spinfab command with the following operands (refer to the HP
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide for more
details).
Example:
[-nmegs count] Specify the number of frames to send in millions.
[-ports list] (Optional) Specify a list of user ports to test.
[-setfail mode] Specify a value 1 to mark failing ports as BAD, specify
a value of 0 to not mark failed ports as bad.
[-domain value] (Optional) Specify a specific remote domain to which
the switch is connected.
switch:admin> setdbg "DIAG", 0
switch:admin> spinfab 3,0,4
spinFab running...
spinFab: Completed 3 megs, status: passed.
port 0 test status: 0x00000000 -- passed.
port 1 test status: 0x00000000 -- passed.
port 2 test status: 0x00000000 -- passed.
port 3 test status: 0x00000000 -- passed.
port 4 test status: 0x02000000 -- SKIPPED!