HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Diagnostic and system error messages reference guide
98 Fabric OS 3.x Document Addendum
DIAG-LCMEMTX
Message
Probable Cause
A central memory transmit path failure occurred: ASIC 1 failed to read ASIC 2 using the
transmit path. This usually indicates a motherboard failure. This message is generated by the
centralmemorytest command. The error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-LCMRS
Message
Probable Cause
A central memory read short occurred; that is, a number of bytes were requested but not
received. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest and cmemretentiontest commands. The error code value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
<timestamp>
CRITICAL DIAG-LCMEMTX, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info> Read Via TX Path,
Word <word number> is <actual value> sb <expected value> er <error value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-LCMRS, 1, <test name>, pass <number>,
Pt<port information> Read Short: is <actual value> bytes sb <expected
value>,
Starting from <starting register>,
Err# <error code>