HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Diagnostic and system error messages reference guide
86 Fabric OS 3.x Document Addendum
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMICKSUM
Message
Probable Cause
The CMI message received failed. This usually indicates an ASIC or motherboard failure. This
message is generated by the cmitest command. The error code value is for internal use
only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-CMICKSUM, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: Pt<src/dst pt> Failed
[good/bad/not target] Cksum Test,
cmi_err bit6 is <actual value> sb <expeted value>, bad msg is from <CMI
bit>,
Err# <error code>