HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Diagnostic and system error messages reference guide
85Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-CMERRPTN
Message
Probable Cause
A problem was detected at the wrong port. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest command. The error code value is
for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMERRTYPE
Message
Probable Cause
The port got the wrong CMEM error type. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest command. The error code value is
for internal use only.
<timestamp>
CRITICAL DIAG-CMERRPTN, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info> Offs <offset value> <err
str> detected at wrong port,
Checking Pt<check pt>: is <actual value> sb <expected value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-CMERRTYPE, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info> Offs <offset value> Wrong
Err Type,
Checking Pt<check pt>: is <actual value> (<err str>) sb <expected value>
(<err str>),
Err# <error code>