DIAG-CAMSTAT
Message
Probable Cause
The ASIC improperly counted the number of frames with CRC errors. This usually indicates
an ASIC failure. This message is generated by the statisticstest command. The
error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CLEAR_ERR
Message
Probable Cause
The port diag error flag (OK or BAD) is cleared. The error code value is for internal use
only.
Recommended Action
No action is required.
Severity
INFO
<timestamp>
CRITICAL DIAG-CAMSTAT, 1, <test name>, pass <number>,
Pt<port information> Failed ALI: <idx>, ALPA: 0x<ALPA number> counter:
<cnt>
Err# <error code>
<timestamp>
INFO DIAG-CLEAR_ERR, 3, Pt<port information> Diagnostics Error Cleared
Err# <error code>