HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Diagnostic and system error messages reference guide
80 Fabric OS 3.x Document Addendum
DIAG-BADINT
Message
Probable Cause
A port received an unexpected interrupt. This usually indicates an ASIC failure. This message
is generated by the centralmemorytest or the cmitest command. The error code
value is for internal use only.
Recommended Action
For the HP StorageWorks SAN Switch 2/16, replace the motherboard FRU.
For the HP StorageWorks SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-BUS_TIMEOUT
Message
Probable Cause
The ASIC register or ASIC SRAM did not respond to an ASIC data access. This usually
indicates an ASIC failure. This message is generated by the portregtest or the
sramretentiontest command. The error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-BADINT, 1, <test name>, pass <number>,
Pt<port information> got interrupt,
int_status=0x<int number> when not expecting one,
Err# <error code>
<timestamp>
CRITICAL DIAG-BUS_TIMEOUT, 1, <test name>,
Pt<port information> BTO accessing <Register Name> Register at Address
<address>,
Err# <error code>