HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Diagnostic and system error messages reference guide
79Fabric OS 3.x Document Addendum
For an unauthorized switch in the SCC policy, add the switch WWN to the SCC policy, using
the secpolicyadd command.
For a certificate retrieve error, make sure the switch certificate is properly installed, using the
pkishow command. Reinstall the certificate, if necessary, using the pkicert command.
For a secret retrieve error, make sure that the secret values are properly set. Reset the secret
values using the secauthsecret command.
For other internal errors (for example, bad payload, incorrect field length, or invalid object),
this might be a transient error. Use the switchdisable and switchenable commands
or portdisable and portenable commands to determine whether the problem is
consistent.
Other errors (for example, invalid nonce, signature, reply message, or response value) might
indicate that an invalid entity is trying to connect to the switch. Check the connection port to
verify that there is no security attack. Otherwise, use the switchdisable and
switchenable commands or portdisable and portenable commands to determine
whether the problem is consistent.
Severity
ERROR
CONFIG-PIDCHANGE_EXTENDED_EDGE
Message
Probable Cause
The PID format for the fabric was changed to Format 2, extended-edge PID. For more
information on PID format, refer to the HP StorageWorks Fabric OS Procedures Version
3.1.x/4.1.x User Guide.
Recommended Action
This message is for information purposes only. The entire fabric must be configured with the
same PID format or the fabric segments.
Severity
WA RN I N G
<timestamp>
WARNING CONFIG-PIDCHANGE_EXTENDED_EDGE, 3, Switch PID format changed to
Format 2 ('Extended Edge PID Format').