On original pages 177 and 178, add the following table after original Figure 42,
“Threshold Configuration Area Configuration Tab”:
Table 6: Threshold Configuration Tab Components
On original page 178, before the section “Threshold Notification Fields Descriptions,”
insert the following sections:
Trait Configuration Tab
Table 7 describes the components of the Trait Configuration tab.
Table 7: Trait Configuration Components
Component Description
Area Selection pull-down
menu
Lists the areas of thresholds that you can configure. The areas
that appear in the pull-down menu depend on the class that
you select from the Fabric Watch Navigation tree.
Trait Configuration tab Provides fields to configure Fabric Watch threshold boundaries
and alarms. For more information, see “Trait Configuration
Tab.”
Alarm Configuration tab Provides fields to configure Fabric Watch alarms. For more
information, see “Alarm Configuration Tab.”
Element Configuration tab Provides fields to configure Fabric Watch threshold traits. For
more information, see “Element Configuration Tab.”
Configuration Report tab Displays the Fabric Watch settings for the class that you select
from the Fabric Watch navigation tree. For more information,
see “Configuration Report Tab.”
Component Description
Unit field Sets or displays the selected unit values used for the chosen area.
Depending on the area of interest, this is figured in units of
downs, reconfigs, errors, changes, logins, and so on.
Time Base pull-down
menu
Sets or displays the basic unit of time in which events are
recorded for the selected area. The units available from the
pull-down menu are none, second, minute, hour, or day.
Low Boundary field Sets or displays the number of low boundaries (the lowest limit at
which an element does not trigger an event) for the selected area.
High Boundary field Sets or displays the number of high boundaries (the highest limit
at which an element does not trigger an event) for the selected
area.
Buffer Size field Sets or displays the threshold boundary buffer size of the selected
area.
Activate Level radio
buttons
Selects either System Default or Custom Defined to indicate which
traits are to be activated.