HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Fabric Watch User Guide
243Fabric OS 3.x Document Addendum
Figure 34: Port Detail Report
Table 22 lists and describes each category in the port detail report.
Table 22: Port Detail Report Columns
>fwportdetailshow
Port Detail Report Report time: 01/16/2004 11:12:28 AM
Switch Name: swd21
IP address: 10.32.243.21
Port Exception report [by All]
--------Port-Errors------------ -----SFP-Errors----
Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC STM SRX STX SCU SV0
--------------------------------------------------------------------------------
000 E HEALTHY 062:11 - - - - - - - - - - - -
001 L HEALTHY 062:11 - - - - - - - - - - - -
002 E MARGINAL 062:11 - - - - - - - X - - - -
003 U OFFLINE 062:11 - - - - - - - - - - - -
004 U OFFLINE 062:11 - - - - - - - - - - - -
005 E MARGINAL 062:11 - - - X - - - - - - - -
006 U OFFLINE 062:11 - - - - - - - - - - - -
007 U OFFLINE 062:11 - - - - - - - - - - - -
008 U OFFLINE 062:11 - - - - - - - - - - - -
009 U OFFLINE 062:11 - - - - - - - - - - - -
010 U OFFLINE 062:11 - - - - - - - - - - - -
011 U OFFLINE 062:11 - - - - - - - - - - - -
012 U OFFLINE 062:11 - - - - - - - - - - - -
013 U OFFLINE 062:11 - - - - - - - - - - - -
014 U OFFLINE 062:11 - - - - - - - - - - - -
015 U OFFLINE 062:11 - - - - - - - - - - - -
016 U OFFLINE 062:11 - - - - - - - - - - - -
Report Item Description
LFA Link loss: the number of link loss occurrences out of range for the time
period
LSY Sync loss: the number of sync loss occurrences out of range for the time
period
LSI Signal loss: the number of signal loss occurrences out of range for the time
period
PER Protocol error: the number of protocol errors out of range for the time
period
INW Invalid word: The number of invalid words out of range for the time period
CRC Invalid CRC: the number of CRC errors out of range for the time period
PSC Port hardware state changed too often due to fabric reconfiguration
STM SFP temperature is out of specifications
SRX SFP receive power is out of specifications
STX SFP transmit power is out of specifications
SCU SFP current is out of specifications
SVO SFP voltage is out of specifications