HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Fabric OS reference guide
222 Fabric OS 3.x Document Addendum
port state The port's state:
No_Card: No interface card present.
No_Module: No module (GBIC or other) present.
No_Light: The module is not receiving light.
No_Sync: Receiving light but out of sync.
In_Sync: Receiving light and in sync.
Laser_Flt: Module is signaling a laser fault.
Port_Flt: Port marked faulty.
Diag_Flt: Port failed diagnostics.
Lock_Ref: Locking to the reference signal.
Testing: Running diagnostics.
Online: The port is up and running.
port
distance
The port's long-distance mode. If a port is configured as a
long-distance port, the long-distance level appears in the format
Lx, where x is the long-distance level number. See
portcfglongdistance for the level description.
comment The comment field either can be blank or display:
Disabled: The port is disabled.
Bypassed: The port is bypassed (loop only).
Loopback: The port is in loopback mode.
E_Port: Fabric port; displays WWN of attached switch.
F_Port: Point-to-point port; displays WWN of attached
N_Port.
G_Port: Point-to-point but not yet E_Port or F_Port.
L_Port: Loop port; displays the number of NL_Ports.
more
comments
The comment field might have additional comments, depending
on the comment field entry.
Disabled A disabled port might have additional comments that explain the
reason for disabling it, such as Persistent or Security violation.
L_Port An L_Port indicates the number for public, private, and phantom
devices in the loop.