HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Fabric OS reference guide
221Fabric OS 3.x Document Addendum
The switch summary is followed by one line per port:
switchState The switch's state: Online, Offline, Testing, or Faulty.
switchMode The switch's mode: Interop or Native.
switchRole The switch's role: Principal, Subordinate, or Disabled.
switchDomain The switch's Domain ID: 0 through 31 or 1 through 239.
switchId The switch's embedded port D_ID.
switchWwn The switch's World Wide Name.
switchBeacon The switch's beaconing state: either ON or OFF.
Zoning The switch's zoning state (either ON or OFF) and effective
zone configuration, within parenthesis.
port number The port number: 0 through 7 or 0 through 15.
module type The port module type (GBIC or other):
No: module present
sw: Shortwave laser
lw: Longwave laser
cu: Copper
id: Serial ID
Use the gbicshow command to display whether a serial ID
GBIC is sw, lw, or cu.
port speed The port's link speed:
1G: Full speed, 1 Gbit/sec.
2G: Double speed, 2 Gbit/sec.
AN: Speed autonegotiation enabled.
N1: Speed negotiated to full speed.
N2: Speed negotiated to double speed.