197Fabric OS 3.x Document Addendum
To display all EE monitors on port 3 for every second (in this example, there are two monitors
on port 3: 0, 1):
See Also
perfaddeemonitor
perfdeleemonitor
Locks a port as a G_Port.
Syntax
portcfggport port_number, mode
Availability
Admin
Description
Use this command to designate a port as a G_Port. The switch then attempts to initialize that
port as only a G_Port.
The switch never attempts loop (L_Port) initialization on the port.
The configuration is saved in nonvolatile memory and is persistent across a switch reboot or
power cycle.
switch:admin> perfShowEEMonitor 3, 1
Showing EE Monitors 3, 1: Tx/Rx are # of bytes and crc is # of crc errors
0 1
------------- -------------
crc Tx Rx crc Tx Rx
============= =============
0 0 1.2k 0 0 1.2k
0 0 272 0 0 272
0 0 136 0 0 136
0 0 272 0 0 272
0 0 272 0 0 272
0 0 204 0 0 204
0 0 204 0 0 204
0 0 136 0 0 136
0 0 272 0 0 272
0 0 272 0 0 272
portcfggport