HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Fabric OS reference guide
196 Fabric OS 3.x Document Addendum
Displays user-defined end-to-end monitors on a port.
Syntax
perfshoweemonitor port [, interval]
Note: This command is deprecated. The perfmonitorshow command should be used instead.
Availability
All users
Description
Use this command to display previously defined end-to-end monitors on a port. When an
interval is not specified or 0 is specified, the command displays the 64-bit cumulative transmit
counter (TX_COUNT), receive counter (RX_COUNT) in Fibre Channel words (4 bytes), and
the 33-bit CRC error counters in hexadecimal format. When a nonzero interval is specified in
seconds, the command displays a rolling table of CRC, Tx and Rx counters on a per-interval
basis for all the valid monitors on the port, in the units of bytes.
End-to-end monitor monitors the traffic on receiving port. See perfaddeemonitor for
more details on how to specify a monitor you want.
Operands
This command has the following operands:
Examples
To display EE monitors on port 3:
perfshoweemonitor
port Specify the port number where you want to display the end-to-end
monitors. This operand is required.
interval Specify the interval in second to monitor CRC_COUNT (CRC),
TX_COUNT (Tx) and RX_COUNT (Rx). Tx and Rx are in unit of byte.
This operand is optional.
switch:admin> perfShowEEMonitor 3
There are 2 end-to-end monitor(s) defined on port 3.
KEY SID DID OWNER_APP OWNER_IP_ADDR TX_COUNT RX_COUNT CRC_COUNT
-------------------------------------------------------------------------------------------------------------------
0 0xb1300 0xb23ef TELNET N/A 0x0000000000000000 0x000000000025ad4f 0x0000000000000000
1 0xb1200 0xb22ef TELNET N/A 0x0000000000000000 0x000000000025ad4f 0x0000000000000000