HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Diagnostic and system error messages reference guide
124 Fabric OS 3.x Document Addendum
SEC-SECVIOL_DCC
Message
Probable Cause
A DCC security violation was reported. The specified device attempted to perform a FLOGI
operation to an unauthorized port. The DCC policy correlates specific devices to specific port
locations. If the device changes connected port, the device is not allowed to perform FLOGI.
Recommended Action
Check the DCC policy and verify that the specified device is allowed in the fabric and is
included in the DCC policy. If the specified device is not included in the policy, add it to the
policy. If the device is not allowed, this is a valid violation message and an unauthorized entity
is trying to gain access to your fabric; take appropriate action as defined by your enterprise
security policy.
Severity
INFO
SEC-SECVIOL_LOGIN
Message
Probable Cause
A login security violation was reported. An incorrect password was used while trying to log in
through a console, telnet, HTTP, or API connection; the login failed.
Recommended Action
Use the correct password.
Severity
INFO
<timestamp>
INFO SEC-SECVIOL_DCC, 4, Security violation: Unauthorized device <device
node name> tries to flogin to port <port number> of switch <port node
name>.
<timestamp>
INFO SEC-SECVIOL_LOGIN, 4, Security violation: Login failure attempt via
<connection method>. Peer IP: <IP address>