HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Diagnostic and system error messages reference guide
111Fabric OS 3.x Document Addendum
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■ For the SAN Switch 2/16, replace the motherboard FRU.
■ For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-XMIT
Message
Probable Cause
The port failed to transmit a frame. This usually indicates an ASIC failure. This message is
generated by the camtest, portloopbacktest, and spinsilk commands. The
error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-XMIT, 1, <test name>, pass <number>,
Pt<port info> Cannot Transmit Frame: <ftx function> returns <error>,
Err# <error code>