HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Diagnostic and system error messages reference guide
110 Fabric OS 3.x Document Addendum
DIAG-TBRAM_WTEST
Message
Probable Cause
The ASIC internal registers failed on a write operation. This usually indicates an ASIC failure.
This message is generated by the turboramtest command. The error code value is for
internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TIMEOUT
Message
Probable Cause
For portloopbacktest and crossporttest:
Port failed to receive frame within timeout period.
For centralmemorytest:
Port failed to detect an interrupt within the timeout period.
This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious
problems in the motherboard or ASIC. The error code value is for internal use only.
<timestamp>
CRITICAL DIAG-TBRAM_WTEST, 1, <test name>, pass <number>,
Pt<port info> Failed TurboRAM write test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
wpat=0x<write pattern>
Err# <error code>
<timestamp>
CRITICAL DIAG-TIMEOUT, 1, <test name>, pass <number>,
Pt<port info> Receive Timeout,
Err# <error code>