HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)

Diagnostic and system error messages reference guide
107Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-STATS (FRX)
Message
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
FramesRx equals the number of frames received. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the portloopbacktest command. The error code value is
for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-STATS (FRX), 1, <test name>, pass <number>,
Pt<port info> FramesRx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>