HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Diagnostic and system error messages reference guide
100 Fabric OS 3.x Document Addendum
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-MEMORY
Message
Probable Cause
The data read from the RAM location did not match previously written data into the same
location. This usually indicates a CPU RAM failure. This message is generated by the
ramtest command. The error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-MEMORY, 1, <test name>,
Memory Error, Address <address value> is 0x<actual value> sb 0x<expected
value> er 0x<err value>,
Err# <error code>