Setup guide
If you have a DVS video device with an ADAT converter, to connect the Lustre
hardware components to the DVS breakout box, refer to the following diagram.
In
Out
Word Clock
110
S/P DIF
Analog Inputs
AES/EBU Out Analog Outputs
3-4
1-2
1-25-67-8
3-45-67-8
12345678
12345678
AES/EBU In
MIDI
In
Out/Thru
ADAT
SYNC
In
Out
ADAT Optical
In
Out
ADAT Converter
IN IN
OUT OUT
IN IN
OUT O UT
VTR
Optical Cable
Audio mixer
IN IN IN IN IN IN IN IN
AUDIO
GPI
IN OUT
IN
DIGITAL AUDIO
OUT
1/2 3/4 7/85/6 1/2 3/4 5/6 7/8
WClk CVBS
RS.422B
RS.422A
LTC
DVS BOB (Front)
To serial port 1
on workstation
(for remote
control of
converter)
Configuring the Lucid ADA 88192 Converter
You must manually configure the Lucid converter for local control. This section
describes how to use the controls on the front of the converter to adjust
settings, and lists the proper settings for local control.
Adjusting Lucid ADA 88192 Converter Settings
You configure the converter through a series of setup menus that appear in
the display on the front of the converter. Use the encoder dial and button
50 | Chapter 3 Connecting System Components