Setup guide
HPxw8400Workstation
(Linux - Incinerator only)
To DVS BOB
0 to co n t rol su rface,
1 to LAN , 3 t o SAN
To GFX monitor
To USB extender for mouse,
keyboard, monitor calibrator
To InfiniBand
switch
To Incinerator
GigE switch
HD-SDI ( V1) Out 4:2:2 t o 4:2:2 or 4:4:4
Ref In from sync gen
HD-SDI ( V2) Out
0:2:2/4:0:0 to 4:4:4
display device or VTR
HD-SDI Out (B) t o
4:4:4 VTR
(dual link 0:2:2)
HD-SDI In (A) f rom 4:2:2
VTR (or 4:4:4 dual link)
HD-SDI Out (A) t o 4:2:2
VTR (or 4:4:4 dual link)
DVI2 Out t o FX5500
SDI daughter card
Connect to second
DVI out on the
main FX5500 card
HD-SDI In (B) from
4:4:4 VTR
(dual link 0:2:2)
Ref In from sync gen
display device or VTR
NOTE The Slave Renderer option is not available for Lustre with Incinerator.
Connecting the Monitor
Connect the monitor to the DVI connection on the Lustre workstation's
graphics card. You can use the DVI extender cable (DL.CAB-HDTV-FO-82-MM)
to extend the cable to a machine room.
To connect the monitor:
➤ Use the DVI cable to connect the DVI OUT1 port of the NVIDIA
®
Quadro
®
FX5500 graphics card to the DVI-D IN port of the monitor.
NOTE Although the DVI fiber cable connectors are identical, their functions
are different. Ensure that the connector labeled Send is connected to the
Lustre workstation, and that the connector labeled Receive is connected to
the monitor.
20 | Chapter 2 Connecting Peripherals