Quick Reference Guide

2 Using the Scanner
Parts of the Scanner
Figure 2-1 Scanner Parts
(1) LED
(2) Scan Window
(3) Nose Boot
(4) Trigger
Scanning Modes
The scanner can operate in one of several scanning modes as described below.
Trigger Single Mode
When the trigger is pulled, scanning is activated until one of the following occurs:
a programmable duration has elapsed
a label has been read
the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning
starts and the product scans until the trigger is released, or a label is read, or the maximum
programmable duration has elapsed.
NOTE: See the Programming Guide (PG) for additional programmable features. In this case:
Scanning Active Time.
ENWW Parts of the Scanner 3